Standard Load Cell for Measuring Weight
A high-precision load cell with a 1KG capacity and MV/V output
- Capacity: 1KG
- Rated output(MV/V): 2.0±0.15
- Accuracy class: C2
- Maximum number of load cell verification intervals (N max): 2000
- Minimum number of load cell verification intervals (V min): EMax/5000
- Combined error(%RO): <±0.030
- Creep(%RO/30min): 0.03
- Temperature effect on sensitivity(%RO/°C): 0.0016
- Temperature effect on zero(%RO/°C): 0.003
- Zero balance(%RO): 1.0
- Input resistance(?): 402±6
- Output resistance(?): 350±3
- Insulation resistance(M? <50V): 5000
- Recommended excitation voltage(V): 10~15
- Compensated temperature range(°C): -10~+40
- Operating temperature range(°C): -35~+80
- Safe overload(%RO): 150
- Ultimate overload(%RO): 200
- Load cell material: Aluminium
- Connecting cable: ø4.2x350mm
- Method of connecting wire: I/P - Red(+), Black(-) O/P - Green(+), White(-)
Top Features:
- 1KG Weight Capacity
- High Precision Output
- Wide Temperature Range
- Aluminium Material
A load cell is a transducer used to convert force into an electrical signal, suitable for applications like electronic platform scales, digital scales, parcel post scales, and electronic balances. The output of this load cell is in millivolts and requires an ADC or an instrumentation amplifier for interfacing with a micro-controller.
For more details or bulk pricing, please contact our sales team directly at sales02@thansiv.com or call +91-8095406416.
Images are for illustration only; actual product may vary.